Owners corporations
Apartment and mixed-use buildings where the committee signs the report but needs one place for every contractor's paperwork.
Commercial and strata facilities management, Melbourne
Office Mon to Fri, 9:00 am to 5:00 pm info@goldenstar.au

Building Regulations 2018, Part 15
Essential safety measures in Victoria are the fire and life safety items in a building, such as exit signs, fire doors, sprinklers and clear paths to exits, that the owner must keep working and report on every year. Golden Star books the inspections, tracks the defects and gathers the records as part of its fire safety services.
The owner, or an agent the owner authorises, then signs the annual essential safety measures report with the evidence already in one place.
ESM inspections by licensed and accredited contractors engaged by Golden Star
The owner's duty
Part 15 of the Building Regulations 2018 puts the duty on the owner. For an owners corporation, that means the committee and strata manager for common property. The owner must:
Older buildings built before July 1994 often have no maintenance schedule on file. The owner still has to keep the measures working, and a municipal building surveyor can issue a maintenance determination that lists them.
Leases
Many commercial leases pass some ESM costs to tenants. Who pays is a matter for the lease, but the legal duty to maintain stays with the owner.

The measures
Each building has its own list, set by its permit, but most commercial buildings share the measures below. The standard shown is the one the maintenance schedule usually refers to.
| Measure | What is checked | Usual standard |
|---|---|---|
| Exit signs and emergency lighting | Six-monthly discharge test on battery; see exit light testing | AS/NZS 2293.2 |
| Extinguishers, hose reels, blankets | Six-monthly inspection and tagging; see fire extinguisher servicing | AS 1851 |
| Fire detection and alarms | Panel, detector and warning system tests | AS 1851 |
| Sprinklers, hydrants and pumps | Valve, pump and flow tests on their routines | AS 1851 |
| Fire and smoke doors | Door closes and latches by itself, seals and tags intact | AS 1851 |
| Exits and paths of travel | Kept clear, doors open without a key from the inside | Building Regulations 2018 |
| Air handling for smoke control | Fire mode operation and dampers | AS 1851 |
This table is a guide. The measures and frequencies that bind your building are the ones on its occupancy permit, maintenance schedule or maintenance determination.
Process
The year runs on the building's maintenance schedule, ending with the annual report. Your site supervisor and operations lead keep each inspection on time and each defect moving.
We collect the occupancy permit, maintenance schedule or determination and the last report, then list every measure and its interval.
Each measure goes to the right licensed or accredited contractor on its interval, from monthly alarm checks to five-yearly tests.
Failed items go on a defect register with a price. We follow each one until it is repaired and retested.
Service reports and logbooks are stored in GS Connect against the building, ready to show an inspector.
Before the anniversary we prepare the annual essential safety measures report for the owner or authorised agent to sign.

Who it is for
Every building in Victoria except a house has essential safety measures if they are listed on its permit. These are the owners and managers who most often hand us ESM compliance.
Apartment and mixed-use buildings where the committee signs the report but needs one place for every contractor's paperwork.
Base building measures for the landlord, with tenancy items tracked where the lease passes them to tenants.
Exits and fire doors that are blocked by stock between visits, so the defect register gets reviewed with centre management.
Inspections fitted around class times, with alarm tests done when children are not on site.
Occupied at night, so tests run in sections and the fire panel is never isolated for longer than needed.
Large sites with long paths of travel, roller doors and racking that can creep into exit routes.
Records
The municipal building surveyor or the fire brigade's chief officer can ask to see these at the building within 24 hours. We keep a copy of each in GS Connect so nothing depends on one folder in a plant room.
Price guide
The cost has two parts: the inspections themselves, priced per item by each trade, and the coordination and annual report. Both depend on the number of measures and how complex the building is.
| Item | From | What changes the price |
|---|---|---|
| Annual report preparation | On quote | Number of measures and whether records are complete |
| Coordination of all ESM inspections | On quote | Number of contractors and visits |
| Inspections by trade | Priced per item on each service page | Extinguishers, exit lights, alarms, doors |
| Catch-up for missing records | On quote | Years of missing logbooks or reports |
Golden Star coordinates essential safety measures for buildings across metropolitan Melbourne, with the most complex lists in CBD and Docklands towers. Other suburbs are on our locations page.
For help with a particular building, send its occupancy permit to info@goldenstar.au.
It depends on how many measures the building has and the state of its records. Send the occupancy permit or maintenance schedule and we will price the inspections and the annual report together.
Each measure has its own frequency on the maintenance schedule, from monthly alarm checks to six-monthly extinguisher and exit light tests and five-yearly tasks. The owner's report is prepared every year on the anniversary of the occupancy permit or maintenance determination.
The owner, or an agent the owner authorises, such as a maintenance contractor. The report must follow the approved form from the building regulator, and it confirms each measure was maintained during the year.
Yes. Every inspection is done by a contractor engaged and checked by Golden Star, inducted to your site rules. Copies of contractor cover sit with our insurance and safety documents for ESM work.
Yes. Alarm tests that sound sirens and fire door checks in busy centres are often booked early or late.
Buildings across metropolitan Melbourne, and regional Victorian buildings where our contractors can service them.
Send the occupancy permit or maintenance schedule and last year's report. We will list every measure, find the gaps and price the year ahead.